Overview
HP StorageWorks Modular Smart Array 500
| |||||
| 1. Display | 5. Power Switch | ||||
| 2. Display Buttons | 6. Status Indicators | ||||
| 3. Display Indicators | 7. Redundant Controller Slot Blank | ||||
| 4. Modular Smart Array Controller | 8. Drive Bay(s) | ||||
|
|
|||||
| 1. Power Supply/Blower Indicators | 4. SCSI Port B | ||||
| 2. Power Supply/Blower Assemblies | 5. SCSI I/O Indicators | ||||
| 3. SCSI Port A | 6. SCSI I/O with Integrated Environmental Monitoring Unit (EMU) | ||||
|
|
|||||
| What's New |
|
| |
| At A Glance |
|
|
|
Standard Features
| Modular Smart Array Family |
| The
HP StorageWorks Modular Smart Array family delivers easy, affordable storage technology
to meet today's demanding and growing IT needs. These storage solutions offer
the best price/performance features for direct attach environments, small clusters,
workgroup sharing and entry-level SAN environments. Each solution is designed
to be easy to deploy, secure, reduce management costs, while driving rapid return
on investment. |
| |
| Modular Smart Array 500 |
| The
HP StorageWorks Modular Smart Array 500 (MSA 500), formerly named Modular Smart
Array 500, is an Ultra3 SCSI (supporting Ultra320 hard drives) storage system,
supporting up to 2TB of data capacity, designed specifically for 2-node clustering
and multiple node (up to 4 servers) shared storage. Designed to reduce the complexity
and expense of clustering and storage sharing, the Modular Smart Array 500 is
built upon Smart Array and ProLiant technologies to provide advanced data protection
features yet is simple to deploy, configure and manage. Ideal for entry level
clustering and shared storage, the Modular Smart Array 500 is familiar SCSI technology,
making it a simple and powerful storage platform. As the customer's clustering
and storage requirements grow, the Modular Smart Array 500 may be converted to
a SAN array by replacing the controller(s) and I/O module and installing a MSA
1000 FC I/O module, or MSA 1000 FC switch, providing the customer with extended
hardware investment protection into the future. The Modular Smart Array 500 combines the array controller shelf and the drive shelf, which holds up to fourteen 1 HP Universal Disk drives in a single 4U rack mount cabinet, that's over 2 terabytes of storage. |
| |
| Key Features |
|
|
|
Product Highlights
| Modular Smart Array 500 Highlights | |
| High Levels of Performance, Data Protection and Functionality |
|
| | |
| DtS (DAS to SAN) Technology | The Smart Array architecture
provides a quick and easy way to migrate from the Modular Smart Array 500
to the Modular Storage Array 1000 (MSA 1000). In order to convert the Modular Smart Array 500 to a SAN, simply remove the Modular Smart Array Controller(s) and replace them with StorageWorks MSA 1000 Controller(s) and add FC I/O board or FC Switch (please refer to MSA 1000 QuickSpecs for additional SAN requirements information). This is referred to as DtS technology (DAS-to-SAN technology). In addition to convertibility to the SAN, the Modular Smart Array 500 allows the seamless migration of stored data in ProLiant servers protected by Smart Array PCI controllers to a Modular Smart Array 500 system. Data that is currently stored on 1" Universal disk drives using HP Smart Array controllers, as well as data on an RA4100 can easily be migrated to the Modular Smart Array 500. Simply remove the drives from the older systems and insert them into the Modular Smart Array 500. Existing data and configuration will remain intact. In addition, the RAID set and data will be preserved allowing migration to be completed in minutes, not hours. |
| | |
| Low Total Cost of Ownership | The modular, scalable design of the Modular Smart Array 500 provides an extremely flexible platform. You can buy what you need today and purchase additional capacity and performance as your data storage needs grow, instead of making a large up-front investment. Additional drives, controllers, and cache can be easily added as your needs dictate.
|
| | |
| Modular Smart Array 500 | The 4U array houses up to fourteen 1" Universal hot pluggable Ultra320, Ultra3 and/or Ultra2 drives. Each Modular Smart Array 500 includes the following standard components: Modular Smart Array 500 Controller, 2-port Ultra3 SCSI I/O Module, dual hot pluggable fans/power supplies, two power cables, two VHDCI SCSI cables and a crossover Ethernet cable. |
|
|
Modular Smart Array 500 Components
| Modular Smart Array 500 Controller | The Modular Smart Array 500 Controller is an integrated RAID controller with an integrated LCD/LED status display and 128-MB read/write battery-backed cache (expandable to 512MB per controller). One Modular Smart Array 500 Controller is included with the Modular Smart Array 500; the redundant Modular Smart Array 500 Controller is an option. |
| | |
| 4-Port Shared Storage Module with Smart Array Multipath |
The 4-Port Shared Storage Module is an option which may be used in one of two configurations:
|
|
| |
| Modular Smart Array 500 Controller Management Features |
|
|
| |
| Controller Firmware Cloning | Enhanced Controller Firmware Auto-Cloning allows customer choice of controller firmware version when adding redundant controller with different firmware version. |
|
|
|
| Multi Host Storage Sharing | Selective Storage Presentation (SSP) support standard on both the base 2-port model of Modular Smart Array 500 as well as the optional 4-port Shared Storage Module. SSP allows the administrator to create volumes and assign access rights to a particular host server. This allows sharing the Modular Smart Array 500 with up to 4 host servers maximizing storage capacity utilization. SSP also allows online capacity expansion as well as online volume extension in DAS configurations. |
|
| |
| RAID |
Several fault tolerant configurations keep data available and servers running
while drives are being replaced, including:
|
|
| |
| Modular Smart Array 500 Controller |
Controller Cache Upgrade |
NOTE: The Modular Smart Array 500 Controller
allows the following cache configurations: 1 x 128 MB; 2 x 128 MB; 1 x
256 MB; 2 x 256 MB |
| Fault Recovery |
|
|
|
|
||
| SCSI I/O Module | The I/O module on
the Modular Smart Array includes an integrated Environmental Monitoring Unit which
performs several functions including monitoring the enclosure functions, providing
I/O connectors and signaling enclosure status. Modular Smart Array 500 ships standard
with a 2-Port I/O Module. The 4-Port Shared Storage Module with Smart Array Multipath is available as an option. The 4-Port Shared Storage Module may be deployed as follows:
|
|
|
Software Components
| The Modular Smart Array 500 utilizes a single, consistent set of utility software for storage and RAID management, setup, configuration and troubleshooting. This consistency reduces the cost of ownership by reducing the training and technical expertise necessary to install and maintain your HP server storage solution. | |
| Configuration Utilities | Array
Configuration Utility (ACU) [On-line for Microsoft and Linux, Remote Web-Based
& Off-line] Option ROM Configuration for Arrays (ORCA) |
| Management/Health Utilities | Insight Manager 7 |
| | |
| Array
Configuration Utility (ACU) |
|
| | |
| Insight
Manager 7 |
|
| | |
| Supported
Operating Systems |
UnitedLinux = Conectiva Linux Enterprise Edition, SCO Linux 4.0, SuSE
Linux Enterprise 8 and TurboLinux 8 all powered by UnitedLinux 1.0 |
|
| |
| Supported
Clustering Solutions |
UnitedLinux = Conectiva Linux Enterprise Edition, SCO Linux 4.0, SuSE
Linux Enterprise 8 and TurboLinux 8 all powered by UnitedLinux 1.0 |
| | |
| Smart Array Multipath Software (Optional) |
Enhance cluster fault tolerance by adding dual paths from the host servers
to the shared storage. This provides an additional level of fault tolerance by
adding redundancy and performance to both the HBA in the host server as well as
the SCSI cables connecting the host servers to the shared storage. Smart Array
Multipath software delivers dual path functionality and supports failover capabilities
for redundant host bus adapters (HBAs) in a server with redundant cabling to a
Modular Smart Array 500. This fault-tolerance tool enhances availability of clustering
and direct attached storage (DAS) solutions with up to two servers managing up
to 2 TB of stored data.
|
| | |
| Warranty | Three-year labor, parts, on-site (3/3/3) Limited Warranty for Modular Smart Array 500. |
|
|
Service and Support, HP Care Pack, and Warranty Information
| Software Product Services |
|
|
| |
| Hardware Product Services |
|
| For additional hardware
installation and maintenance information, please refer to the URLs listed below: http://h18005.www1.hp.com/services/carepaq/us/install/ http://h18005.www1.hp.com/services/carepaq/us/hardware/ | |
| | |
| Warranty Upgrade Options |
|
| HP Care Pack is defined as an upgrade to the product warranty attribute, available for a specific duration and hours of coverage. | |
| |
| For
additional HP Care Pack (hardware & software) information, as well as orderable
part numbers, please refer to the URL listed below: http://h18005.www1.hp.com/services/carepaq/index.html | |
| | |
| HP Care Pack Description (U.S. Only) | 9x5, 4-Hour Response, On-Site Coverage, 3 years |
402165-002
|
| 24x7, 4-Hour Response, On-Site Coverage, 3 years |
402164-002
|
|
| Hardware Installation |
402162-002
|
|
|
|
||
| HP Care Pack Description (EMEA Only) | 9x5, 4-Hour Response, On-Site Coverage, 3 years |
160875-022
|
| 24x7, 4-Hour Response, On-Site Coverage, 3 years |
160883-022
|
|
|
|
||
| HP
Care Pack Description (Canada Only) | 9x5, 4-Hour Response, On-Site Coverage, 3 years |
FP-FC4HR-36 |
| 24x7, 4-Hour Response, On-Site Coverage, 3 years |
FP-FC724-36 | |
| Hardware Installation (on site) |
FP-FCINS-IN |
|
|
Configuration Information
| Step 1: Order Required Items |
|
Models | HP Modular Smart Array 500 Starter Kit (includes MSA 500 and 2 SA-532 Adapters) |
351504-B21 |
| HP Modular Smart Array 500 | 201724-B21 | |
| | ||
|
Package Contents | 4U Modular Smart Array 500 | |
| Modular Smart Array 500 Controller with 128 MB cache | ||
| 2-port SCSI I/O Module | ||
| Redundant Hot Pluggable Power Supply/blower assemblies | ||
| Modular Smart Array 500 Rack Mounting Kit | ||
| Modular Smart Array 500 Support Software or Smart Start | ||
| Power cables (2) | ||
| VHDCI SCSI cables 6' each (2) | ||
| Crossover Ethernet cable for clustering | ||
| User Manual | ||
| Smart Array 532 Adapters (2) Included in "MSA500 Starter Kit Only" | ||
| | ||
| Step 2: Choose Modular Smart Array 500 System Options |
|
Options
|
Modular Smart Array 500 High Availability Kit (includes MSA500 controller, 4-port IO Module, Smart Array Multipath Software and 2 SA-532 Adapters) |
351281-B21
|
| Modular Smart Array 500 Controller | 218252-B21 | |
| 4-Port Shared Storage Module with Smart Array Multipath Software |
292944-B21
|
|
| 128MB Battery Backed Cache Module |
153506-B21
|
|
| 256MB Battery Backed Cache Module |
254786-B21
|
|
| M-Series Rack Rail Kit Option |
313877-B21
|
|
| NOTE:
The Modular Smart Array 500 Controller allows the following cache configurations:
1 x 128 MB; 2 x 128 MB; 1 x 256 MB; 2 x 256 MB. NOTE: When redundant controllers are installed, the cache configurations in both controllers must be identical. |
||
|
|
||
| Step 3: Choose ProLiant Server(s) |
|
Server Compatibility | ML330 G2 (Direct Attached and RSO configurations only) | |
| ML330 G3 (Direct Attached and RSO configurations only) | ||
| ML350 G2 (Direct Attached and RSO configurations only) | ||
| ML350 G3 (Clustering, Direct Attached and RSO configurations) | ||
| ML370 G2 (Clustering, Direct Attached and RSO configurations) | ||
| ML370 G3 (Clustering, Direct Attached and RSO configurations) | ||
| DL360 G2 (Clustering, Direct Attached and RSO configurations) | ||
| DL360 G3 (Clustering, Direct Attached and RSO configurations) | ||
| DL380 G2 (Clustering, Direct Attached and RSO configurations) | ||
| DL380 G3 (Clustering, Direct Attached and RSO configurations) | ||
| DL560 (Clustering, Direct Attached and RSO configurations) | ||
| DL580 (Clustering, Direct Attached and RSO configurations) | ||
| DL580 G2 (Clustering, Direct Attached and RSO configurations) | ||
| DL740 (Clustering and Direct Attached configurations) | ||
| DL760 (Clustering and Direct Attached configurations) | ||
| DL760 G2 (Clustering and Direct Attached configurations) | ||
| | ||
| Step 4: Choose Host Connectivity (Skip If Purchased MSA500 Starter Kit) |
| NOTE: Some of the options listed below may be discontinued |
|
Required for ML330 G2, ML350 G2, ML350 G3, ML370 G3, DL360
G2, DL360 G3, DL580, DL580 G2, DL760 | Smart Array 532 Controller Option Kit |
225338-B21 |
| Smart Array 532 Controller Option Kit (Japan) |
225338-291 | |
| | ||
|
Required for ML370 G2
|
Smart Array 532 Controller |
225338-B21
|
| Smart Array 532 Controller (Japan) |
225338-291
|
|
| Smart Array 5i Controller Option Kit |
226593-B21
|
|
| Smart Array 5i Controller Option Kit (Japan) |
226593-291
|
|
| NOTE: Either one Smart Array 532 Controller or one Smart Array 5i or Smart 5i Plus Controller Option Kit is required. | ||
|
|
||
|
Optional for DL380 G2
|
Smart Array 532 Controller Option Kit |
225338-B21
|
| Smart Array 532 Controller Option Kit (Japan) |
225338-291
|
|
| NOTE: The Smart Array 5i controller is included with the ProLiant DL380 G2. No additional adapter required unless implementing Smart Array Multipath technology | ||
|
|
||
|
Optional for DL380 G3 | Smart Array 532 Controller Option Kit | 225338-B21 |
| Smart Array 532
Controller Option Kit (Japan) | 225338-291 | |
| NOTE: The Smart Array 5i Plus controller is included with the ProLiant DL380 G3. No additional adapter required unless implementing Smart Array Multipath technology | ||
| | ||
| Step 5: Choose Configuration Options |
|
High Availability Software
|
ProLiant Essentials Recovery Server Option (RSO) |
280189-B21
|
| HP Serviceguard for
Linux ProLiant Cluster |
305199-B24
|
|
| HP Serviceguard for Linux License |
307754-B24
|
|
| NOTE: Above options not required for Microsoft clustering, Novell clustering or non-clustered shared storage configurations | ||
|
|
||
| Step 6: Choose Hard Drives |
|
Pluggable, Universal Hard Drives
|
72.8-GB 10,000 rpm, U320 Universal Hard Drive (1") | 286714-B22 |
| 146.8-GB 10,000 rpm, U320 Universal Hard Drive (1") | 286716-B22 | |
| 300-GB 10,000 rpm U320 Universal Hard Drive (1") | 350964-B22 | |
| 36.4-GB 15,000 rpm, U320 Universal Hard Drive (1") | 286776-B22 | |
| 146.8-GB 10,000 rpm U320 Universal Hard Drive (1") | 347708-B22 | |
| 72.8-GB 15,000 rpm, U320 Universal Hard Drive (1") | 286778-B22 | |
| NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3 speeds. U320 drives require an optional U320 Smart Array Controller or U320 SCSI HBA to support U320 transfer rates. | ||
| NOTE: For complete compatibility information, refer to the HP SCSI Hard Drive Compatibility table located at http://www.compaq.com/products//hdd/hotplug.html | ||
|
|
||
| Step 7: Choose Rack Option |
| HP Rack 5000 Series | HP 5642 RACK - UNASSEMBLED |
358254-B21
|
| HP Options for Rack 5000 Series | Stabilizer Kit for
5642 rack (Graphite Carbon) NOTE: The stabilizing kit is used to prevent rack from tipping over. |
374493-B21
|
| Baying Kit for 5642
rack (Graphite Carbon) NOTE: The baying kit is used to join two or more HP 5642 racks. |
374499-B21
|
|
|
HP Rack 10000 Series (Graphite Metallic)
|
Rack, HP Infrastructure
42U (HV) |
379005-001
|
| Rack, HP Infrastructure 42U (LV) |
379006-001
|
|
| HP Rack S10614 (14U) Rack Cabinet - Shock Pallet |
292302-B22
|
|
| HP Rack 10842 (42U, 800mm wide) - Pallet |
257415-B21
|
|
| HP Rack 10842 (42U, 800mm wide) - Shock Pallet |
257415-B22
|
|
| HP Rack 10647 (47U) - Pallet |
245160-B21
|
|
| HP Rack 10647 (47U) - Crated |
245160-B23
|
|
| HP Rack 10642 (42U) - Pallet |
245161-B21
|
|
| HP Rack 10642 (42U) - Shock Pallet |
245161-B22
|
|
| HP Rack 10642 (42U) - Crated |
245161-B23
|
|
| HP Rack 10636 (36U) - Pallet |
245162-B21
|
|
| HP Rack 10636 (36U) - Shock Pallet |
245162-B22
|
|
| HP Rack 10636 (36U) - Crated |
245162-B23
|
|
| HP Rack 10622 (22U) - Pallet |
245163-B21
|
|
| HP Rack 10622 (22U) - Shock Pallet |
245163-B22
|
|
| HP Rack 10622 (22U) - Crated |
245163-B23
|
|
| NOTE:
-B21 (pallet) used to ship empty racks shipped on a truck -B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels) -B23 (crated) used for air shipments of empty racks. |
||
| NOTE: It is mandatory to use a shock pallet in order to ship racks with equipment installed. | ||
|
|
||
| Step 8: Expansion Options |
|
SAN Conversion Options
|
Modular Smart Array 1000 Controller |
218231-B22
|
| MSA Fibre Channel I/O Module |
218960-B21
|
|
| MSA SAN Switch 2/8 (Integrated) |
288247-B21
|
|
| FAC2214 Host Adapter (Microsoft/Linux) |
281541-B21
|
|
| 2Gb/s SFP SW Transceiver Kit |
221470-B21
|
|
| Modular Smart Array 30 Single Bus (rack-mountable) |
302969-B21
|
|
| NOTE:
The MSA 1000 controller and the MSA 1000 Fibre Channel I/O module (or
the MSA SAN Switch 2/8) are required for conversion. To obtain conversion
procedure document go to http://www.hp.com/go/msa500
and download "Converting Modular Smart Array 500 to a Modular Smart
Array 1000 for Additional Scalability document. |
|
|
Technical Specifications
| Modular Smart Array 500 Controller |
| LED Indicators on Front (3) | Power | |
| Fault detected in one or more sub-systems | ||
| Fault in Enclosure Management | ||
| LED Indicators for Drive Modules (3) | Drive Access (center) | |
| Online (left) | ||
| Drive Failure (right) | ||
| LED Indicators on Rear Panel (4) | Power Supply/Blower Assembly Fault (1) | |
| EMU (3): Power; A bus; B bus | ||
| Interface | Ultra3 SCSI to Hard Drives | |
| Ultra3 SCSI to Host Servers | ||
| Maximum Number of Drives | 14, 1-in Ultra320, Ultra3 or Ultra2 Universal Hard Drives (Modular Smart Array 500 cabinet) | |
| Temperature Range | Operating | 50° to 95° F (10° to 35° C) |
| Shipping | -2°
to 122° F (-0° to 50° C) NOTE: Rated 1°C per 1000 feet of elevation to 10000 ft. | |
| Relative Humidity | Operating | 10% to 90% |
| Non-operating | Up to 95% | |
| Input Power Requirements | Rated Input Voltage | 100 to 240 VAC |
| Rated Input Frequency | 50 to 60 Hz | |
| Rated Input Current | 2.3 A at12 VAC typical, 6A Maximum | |
| Input Power (max) | 549 W* | |
| Heat Dissipation (maximum) | 1876 Btu/hr* | |
| *Input Power and Heat Dissipation specifications are maximum values and apply to worst-case conditions at full rated power supply load. The power/heat dissipation for your installation will vary depending on the equipment configuration. | ||
| 2-Port SCSI I/O Module | Ports | 2 VHDCI Ultra3 SCSI ports |
| Dimensions | 4.5 x 1.375 x 9.5 in (11.4 x 3.5 x 24.1 cm) | |
| Weight | 1.3 lb (0.6 Kg) | |
| Modular Smart Array 500 Cabinet | 4U Rack Form Factor | |
| Dimensions (H x W x D) | 6.9 x 19 x 20.5 in (17.5 x 48.3 x 52.1 cm) | |
| Weight (Net) | 50 lb (22.5 kg) | |
| Shipping Packaging | Dimensions (L x W x D) | 33.7 x 14.8 x 33.8 in (85.6 x 37.5 x 85.9 cm) |
| Weight (Gross) | 70 to 105 lb (31.5 kg) | |
| | ||
| Modular Smart Array 500 Controller |
| User Interface | Controller
Display with Status Indicators (2) and Push Buttons (4) Status Indicators on front of Controller (16) | |
| Electrical Interface | LVD (Low Voltage Differential) | |
| Protocol Support | Wide Ultra3 SCSI (160 MB/s per channel) | |
| SCSI Ports | 2 external VHDCI connectors standard. Optional 4-Port Shared Storage Module with 4 VHDCI connectors. | |
| Drives Supported | Up to 14 drives | |
| Maximum Capacity | 2.0 TB (14 drives x 146.8GB) | |
| Logical Drives | Up to 32 logical drives | |
| RAID Support | RAID ADG (Advanced Data Guarding) | |
| RAID 5 (Distributed Data Guarding) | ||
| RAID 1+0 (Striping & Mirroring) | ||
| RAID 1 (Mirroring) | ||
| RAID 0 (Striping) | ||
| Cache Memory | Standard 128 MB Read/Write Cache | |
| Up to 512 MB Read/Write | ||
| ECC protection, battery-backed, and removable | ||
| NOTE:
The Modular Smart Array Controller allows the following cache configurations: 1 x 128 MB; 2 x 128 MB; 1 x 256 MB; 2 x 256 MB. | ||
| NOTE: When redundant controllers are installed, the cache configurations in both controllers must be identical. | ||
| Cache Batteries | Up to three days of redundant battery life, removable for easy replacement | |
| Upgradeable Firmware | 2 MB flashable ROM | |
| Disk Drive and Enclosure Protocol Support | Ulltra320, Ultra3 and Ultra2 SCSI 1-inch Universal drives | |
| Packaging | Dimensions (L x W x D) | 14.5 x 11.5 x 3.1 in (36.8 x 29.2 x 8 cm) |
| Weight (Gross) | 6 lb (2.72 kg) | |
| | ||
| 4-port Shared Storage I/O Module (option) |
| Connector Type | VHDCI Ultra3 SCSI | |
| Ports | 4 Ultra3 SCSI | |
| Bandwidth | 160 MB/s per port | |
| Protocols/HBA Supported | Ultra320, Ultra3 and Ultra2 SCSI/Smart Array 532, Smart Array 5i adapters | |
| Packaging | Dimensions (L x W x D) | 14.5 x 11.5 x 3.1 in (36.8 x 29.2 x 8 cm) |
| Weight (Gross) | 6 lb (2.72 kg) | |
| | ||
| MSA500 High Availability Kit (option) |
| Contents | MSA500 Controller, 4-port Shared Storage I/O Module, 2 6ft. SCSI Cables, 2 SA-532 Adapters, and Smart Array Multipath Software 2.0 | |
| Packaging | Dimensions (L x W x D) | 22.6 x 18.6 x 12.4 in (57.5 x 47.3 x 31.4 cm) |
| Weight (Gross) | 14.2 lb (6.5 kg) | |
| | ||
|
© Copyright 2004 Hewlett-Packard Development Company, L.P. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |