The iLO2 Driver Did Not Get Installed Even Though The Windows Server 2003 x64 Deployments Are Successful
Article: 20000009
Applies to: Release 6.x
When deploying Windows Server 2003 x64, either via a scripted install or Sysprep imaging, to older ProLiant servers,
the job will be successful, but the iLO2 driver will not get installed.
This means that there will be no one-time boot support.
This issue occurs because the script used to install the included smart components was unable to determine
that the target server was a ProLiant.
To resolve this issue, remote desktop to the target server and manually install the included smart components
in c:\$oem$\components.
The servers impacted are
| |
DL145 G2 |
| |
DL145 G3 |
| |
DL380 G4 |
| |
DL385 |
| |
DL580 G3 |
| |
DL580 G4 |
| |
ML310 G3 |
| |
ML310 G4 |
| |
ML350 G4 |
| |
ML370 G4 |
|